Civil Engineering homework help

New York City College of Technology
Department of Construction Management and Civil Engineering Technology
SOIL MECHANICS PROJECT
CMCE 2456 – Fall 2020
A homeowner want to level a rear yard. You visit the site and realize that the work will require the
construction of an about 5-ft-tall retaining wall. Your subsurface exploration indicates that the soil
in the yard is homogeneous medium to fine SAND with trace amounts of silt (USCS Classification
SP) to a depth of 25 ft below ground surface. N-values suggest that the material is classified as
NYC Building Code Class 3b material; groundwater was not encountered. Laboratory tests
indicate that the sand has a moist unit weight of 122 pcf and an angle of internal friction of 33°.
PROBLEM STATEMENT
Size the retaining wall such that it has a geotechnical factor of safety against sliding and
overturning of 1.5.
Assumptions
 Assume a vertical surcharge of 300 psf is applied on the high side of the wall.
 The wall foundation must bear 4 ft below the lowest grade for frost protection.
 The stem of the wall must be a minimum of 12-inches thick.
 The wall footing must be a minimum of 12-inches thick.
 Ultimate friction factor for mass concrete against clean fine to medium SAND is 0.4.
 Consider passive pressure in the analysis.
 Lateral pressures due to the surcharge have a uniform distribution based on a pressure
equal to 50 percent of the vertical pressure.
 Unit weight of reinforced concrete is 150 pcf.
Assignment
1) Produce an engineered-quality scaled drawing.
2) Include your calculations showing your assumptions, pressure diagrams and resultant
forces.
3) What is the applied bearing pressure under the wall?
4) Is the applied pressure less than the Building Code allowable?
5) If passive pressure is discounted, what is the resulting factors of safety?
6) Provide a cover letter with your submittal.
NOTE: Your calculation must be on engineering paper, they must be neat and without
scribbled corrections.

Civil homework help

3-4 Paragraph Discussion

Do you believe government should regulate businesses? Why or why not? Support your belief.

Project

Your task is to write a 1-page professional letter to the Roadrunner Insurance Company that addresses the probable cause of the chimney failure as well as the approximate month and year the failure began. In your letter, you must offer a reasonable and logical explanation for the chimney failure that is: (1) consistent with the photos you took and the information provided to you by the homeowner, and (2) related to the chimney’s and/or the house’s engineering.
Your letter must also offer an approximate time period for when the failure began. Finally, your letter must reference by figure number each of the 8 photos that should be included with the letter. Your letter should precede the photos. Beyond these requirements, for the purposes of this assignment, you may fabricate details such as reasonable weather events consistent to the time and area, natural disasters that may have occurred in the time and area, soil erosion, and so forth.
Attached for your review are CE Writing Project lessons on (1) Using Figures and Tables, (2) Information Flow in Sentences, (3) Sequence of Information in a Report, and (4) Cover Letters. You will be held accountable to the information in these documents.
In your writing, please take care to proofread your work and utilize the knowledge you’ve acquired from the language and grammar CE Writing Project lessons you’ve been assigned to read. The written portion of your Project 4—Failure Analysis Letter should be typed in a professional looking font in 10-12 point size.